Series 8800MPHT Insertion Thermal Mass Flow Meter High Temperature

This series meter is great for high temperature applications  See specifications.

Description

Below is our insertion style high temperature meter. Model numbers based on probe OD.

8800mpht_dim.png

Master-Touch™ Series 8800MPHT Flow Meters

MPHT Series flowmeters are great for high temperature applications (see specifications)

Insertion style thermal mass flowmeters include a sensor & probe assembly that is inserted into the process gas flow conduit to allow the process gas to flow across the flow sensing elements. Our insertion style flowmeters are available with 3/4″, or 1″ OD probes. Tube fittings and ball valve retractor assemblies, with or without a mounting flange, are also available from the factory as options. The tube length must be specified upon ordering. For other probe diameters and lengths, please consult the factory.

Integral style thermal mass flowmeters have all of the electrical components and connections located within one enclosure. The enclosure is mounted directly to the insertion probe assembly at the point of measurement. The enclosure includes the all of the electrical connections as well as the linearizing electronics and the display/keypad assembly.

Thermal mass flowmeters use the principle of convective heat transfer to directly measure mass flow. EPI’s proprietary thermal mass flow sensors use two ratiometrically-matched, reference-grade platinum Resistance Temperature Detectors (RTDs). The platinum sensing element wire is encapsulated in a 316 Stainless Steel sheath or, if specified, a Hastelloy C sheath. Our microcontroller operated smart sensor technology preferentially heats one RTD; the other RTD acts as the temperature reference. The process gas flow dissipates heat from the first RTD, causing an increase in the power required to maintain a balance between the RTDs. This increase is directly related to the gas molecular rate of flow. Our sensors are temperature compensated for a wide process gas temperature range and insensitive to pressure changes, so the output signal is a true mass flow rate signal.

Approvals:
Currently no agency approvals

Linear signal output
0–5 VDC & 4–20 mA (Flow and Temperature)

Signal Interface
RS232 & RS485 Modbus RTU embedded
Optional HART or Profibus DP

LCD (flow rate, flow total, gas temperature)

Accuracy, including linearity (Ref.: 21°C)
±(1% of Reading + 0.5% of Full Scale + GTC)

Repeatability
±0.2% of Full Scale

Sensor response time
1 second to 63% of final value

Turn down ratio
100:1 @ 15 SFPM (.076 NMS) Minimum Reading

Electronics PCB temperature range
-40° to 158°F (-40° to +70°C)

Environmental temperature range
-40° to 140°F (-40° to +60°C)

Gas temperature range
-40°–977°F (-40°–525°C) 

Gas temperature coefficient (GTC)
0.02% Full Scale/°C

Gas pressure effect
Negligible over ± 20% of absolute  calibration pressure

Pressure rating maximum
500 PSI Std.

Input power requirement
24VDC @ 250mA
115 VAC 50/60 Hz optional
230 VAC 50/60 Hz optional

Flow Transmitter power requirements
5 watts maximum

RAM Back-up
Lithium Battery

Wetted materials
316 Stainless Steel (Hastelloy optional)

Standard temperature & pressure (STP)
70°F & 29.92″ Hg (Air .075 lb./cubic foot)

NIST traceable calibration
Standard

NOTE: Specification subject to change without notice.